Assumptions:
HP 3PAR Adaptive Flash Cache is a feature that uses SSDs for read cache. It can be used to maximize read hits and improve
random read performance.
Flash Cache can be created in 16 GB increments.
Flash Cache is always created as fully allocated RAID 1 Logical
Disks behind all nodes on the array
Feature can be enabled on entire system rather or on VVSet
Mode.
We will activate on entire system:
Verify available space:
DC13PAR cli% showspace -p -devtype SSD -t r1 -ha mag
--Estimated(MB)---
RawFree UsableFree
1896448 948224
Verify if Flash Cache is already configured:
DC13PAR cli% showflashcache
If is enabled you will see an output similar to:
-(MB)-
Node Mode State Size Used%
0 SSD normal 65536 41
1 SSD normal 65536 41
2 SSD normal 65536 45
3 SSD normal 65536 41
-------------------------------
4 total 262144
And you should skip the createflashcache step.
If it`s not configured carry on with the next step:
Create 128 GB (or as much as you need) of Flash Cache for
each node pair in the array:
DC13PAR cli% createflashcache 128g
Verify again with showflashcache and go to next step.
We will now enable Flash Cache on entire system, as stated at the beginning using following command:
DC13PAR cli% setflashcache enable sys:all